MV-22 Emergency Egress Lighting System Charger/Analyzer
I designed a two-board bench instrument to charge the internal NiCd batteries, verify the inhibit function, and test the NVG and white-light outputs of the MV-22 emergency lighting assembly.
Aerospace Electronics & Test Engineering
- Affiliation
- United States Marine Corps
- Classification
- Aerospace diagnostic equipment development
- Stage
- Documented engineering work
Maintenance problem and engineering question
Emergency-egress lighting provides an illuminated reference to aircraft exits when normal cabin illumination is unavailable or visibility is degraded. Battery-backed designs make stored energy and electrical function separate maintenance concerns.1 A completed charge cycle alone does not establish that the enable, inhibit, and lighting-output functions respond correctly.
At Marine Aviation Logistics Squadron 24, the shop had no local means to perform the MV-22 Emergency Egress Lighting System (EELS) operational check. The engineering question was how to bring battery charging, commanded-state verification, and independent lighting-output checks into one practical, observable bench configuration.
Test architecture and operating functions
I designed and developed an original EELS charger/analyzer that integrated battery charging, control-state verification, and lighting-output evaluation into a dedicated bench instrument. The design incorporated two custom printed circuit boards and an operator interface organized around the assembly’s electrical test requirements. The instrument charged the assembly’s internal nickel-cadmium (NiCd) batteries across the supported charging conditions, with automatic charge termination. Dedicated controls allowed the technician to verify the inhibit response and independently enable and check the night-vision-goggle (NVG) and white-light outputs.
The panel brought operating-state selection, lighting and load controls, supply indication, and measurement access into one interface. The technician could check whether the battery could be charged, whether the assembly respected the commanded control state, and whether each lighting circuit responded. Separate checks were necessary because a working output on one circuit did not establish correct operation of the other.
Documented configuration and physical integration
| Function | Implemented capability or visible interface |
|---|---|
| Battery service | Internal NiCd charging with automatic charge termination. |
| Control states | Separate ENABLE 1, ENABLE 2, and INHIBIT controls. |
| Lighting and loads | LIGHT 1 / LIGHT 2 and LOAD 1 / LOAD 2 selectors. Independent NVG and white-light output checks. |
| Measurement access | Fourteen numbered test points, TP1–TP14, and connections labeled FREQ 1 and FREQ 2. |
| Test-set power connections | Terminals labeled 5 VDC and 18 VDC. A separate inlet labeled 120 VAC, 60 Hz, COOLING POWER. |
| Physical construction | Two circuit boards, panel wiring, mechanical supports, a metal enclosure, and active cooling. |
The photographs illustrate the integration of the circuit assemblies, operator controls, wiring, and mechanical supports. Accessible measurement points allowed electrical behavior to be examined alongside the selected operating state. Active cooling and enclosure ventilation addressed heat generated during bench operation, while the separate cooling control made that function available at the instrument panel.
One of the two boards was my first PCB design produced by a professional fabricator. Translating the electrical design into a fabricated assembly required decisions about component placement, copper routing, mounting features, and the connections to the enclosure wiring. The PCB photograph shows the board during assembly. The interior view above shows how the two boards fit within the finished instrument.
Engineering review and maintenance outcome
At the close of the 2018 award period, the Naval Aviation Fleet Support Team at Miramar was reviewing the design. Subsequent approval enabled intermediate-level maintenance personnel to perform the operational check.
The resulting capability was a local means of charging the assembly, verifying inhibit behavior, and evaluating each lighting output. The project combined original circuit design, custom PCB development, electrical diagnostics, thermal provisions, and electromechanical integration to turn a maintenance requirement into working bench equipment.
1 General emergency-egress-lighting context. Astronics, Emergency Lighting, HEEL Lighting section.
Technical areas
Circuit and test-equipment design, Battery and electrical diagnostics, Custom circuit-card development, Electromechanical integration, Aviation engineering coordination.
Paul G. Vess Avionics Marine of the Year →