Kyle M. LeClairEngineering & Applied Research

Engineering Portfolio

AH-1W Caution Advisory System Diagnostic Test Set

I built a hand-wired bench interface for the AH-1W master caution light, audible alarm, and individual annunciator channels. The average operational check fell from 90 minutes to 10 minutes.

Aerospace Electronics & Test Engineering

Affiliation
United States Marine Corps
Classification
Applied test-equipment engineering
Stage
Documented engineering work

A bench check for a cockpit warning system

At Marine Aviation Logistics Squadron 24, a repaired AH-1W Super Cobra caution advisory assembly could occupy a technician for another 90 minutes before it was ready to return to supply. The master caution light could illuminate and still leave an important question unanswered. Would the system identify the particular caution or advisory and give the pilot the corresponding indication?

I designed and fabricated a test set that brought those checks to one bench interface. I began with the aircraft wiring schematics and traced the functions that a maintainer needed to exercise, from the electrical interfaces to the indications the crew would see or hear. The first working unit, built from spare switches, connectors, and wire, is pictured below.

First AH-1W test set in a translucent plastic enclosure. A rotary selector sits to the right of labeled switches and five test jacks.
The original hand-wired prototype. The clear enclosure shows the wiring behind the controls. A 24-position selector and labeled test points made a series of individual checks practical at the bench.

From an individual caution to the pilot’s indication

The selector gave the technician a way to exercise individual caution and advisory channels. A channel check asked whether a selected condition produced the expected annunciation. The master caution light and audible alarm were also within the test set’s scope, as was the pilot-initiated test function. These checks answered different questions. A successful pilot test established that the assembly could respond to that command. Checking individual channels established whether it responded correctly to each selected condition.

I extended the interface to the current amplifier, the multiplexer (MUX), and the flight computer input/output connections associated with the caution advisory system. That coverage mattered when a cockpit indication was missing. The symptom alone could not tell a technician which electrical interface needed attention. Bringing the relevant functions and measurement points to the panel gave the technician a way to investigate a discrepancy and verify the repaired assembly.

From prototype to shop equipment

The plastic enclosure was the first of several sets built. Its purpose was to prove that the shop could reproduce the required electrical conditions with the components on hand. A labeled selector also made the check easier to repeat. The next technician could identify the channel under test directly from the panel.

The average operational check fell from 90 minutes to 10 minutes, freeing about 80 minutes of technician time per check. Across the wider repair and supply cycle, the reported time to replenish these assets fell from 28 days to 17 days. The project was recognized in my Navy and Marine Corps Commendation Medal documentation and in the work cited for the Paul G. Vess Award.

Technical areas

Electrical schematic interpretation, Diagnostic interface design, Functional verification, Maintenance process improvement.

Paul G. Vess Avionics Marine of the Year →

MV-22 EELS charger/analyzer →

← Aerospace Electronics & Test Engineering