PCB conductor resistance & voltage drop
Estimate the DC resistance, voltage drop, and power loss of a single copper trace at a specified conductor temperature.
Calculated values
- DC resistance
- —
- Voltage drop
- —
- Power loss
- —
Method and assumptions
The model treats a single trace as a straight, uniform rectangular conductor. Resistance depends on the finished copper cross-section and the temperature of the conductor.
ΔV = IR · P = I²R
L, w, and t are length, width, and finished thickness in metres. T is uniform copper temperature in °C. I is current in amperes. Unit conversions use 1 in = 25.4 mm and 1 mil = 0.001 in.
The reference conductivity of 100% IACS annealed copper at 20 °C is 58 MS/m, giving ρ20 ≈ 1.72414 × 10−8 Ω·m. The linear resistance coefficient α20 is 0.00393 °C−1. Source: U.S. Bureau of Standards, Copper Wire Tables, Circular 31 (PDF).
This first-order DC estimate excludes self-heating, contact and via resistance, return paths, plating variations, and frequency-dependent losses. A separate thermal assessment is required for ampacity, IPC compliance, or safety qualification.
Reproducible examples
Both cases use a 100 mm long, 1 mm wide trace with 35 µm finished copper. The values below are rounded analytical checks.
| Copper temperature | Current | Resistance | Drop | Loss |
|---|---|---|---|---|
| 20 °C | 1 A | 49.261 mΩ | 49.261 mV | 49.261 mW |
| 70 °C | 2 A | 58.941 mΩ | 117.88 mV | 235.76 mW |