Estimate the DC resistance, voltage drop, and power loss of a single copper trace at a specified conductor temperature.

Software & Tools  /  Printed circuit design  ·  Version 1.0.0

Trace parameters

Enter positive finished dimensions. Use the copper temperature (−40 to 125 °C) and a nonnegative current magnitude.

Calculated values

DC resistance
—
Voltage drop
—
Power loss
—

Method and assumptions

The model treats a single trace as a straight, uniform rectangular conductor. Resistance depends on the finished copper cross-section and the temperature of the conductor.

R=ρ20Lwt[1+α20(T−20)]

ΔV = IR   ·   P = I²R

L, w, and t are length, width, and finished thickness in metres. T is uniform copper temperature in °C. I is current in amperes. Unit conversions use 1 in = 25.4 mm and 1 mil = 0.001 in.

The reference conductivity of 100% IACS annealed copper at 20 °C is 58 MS/m, giving ρ20 ≈ 1.72414 × 10−8 Ω·m. The linear resistance coefficient α20 is 0.00393 °C−1. Source: U.S. Bureau of Standards, Copper Wire Tables, Circular 31 (PDF).

This first-order DC estimate excludes self-heating, contact and via resistance, return paths, plating variations, and frequency-dependent losses. A separate thermal assessment is required for ampacity, IPC compliance, or safety qualification.

Reproducible examples

Both cases use a 100 mm long, 1 mm wide trace with 35 µm finished copper. The values below are rounded analytical checks.

Copper temperatureCurrentResistanceDropLoss
20 °C1 A49.261 mΩ49.261 mV49.261 mW
70 °C2 A58.941 mΩ117.88 mV235.76 mW